100% efficient motion corrected coronary MR angiography using a gradient echo sequence in a 3T PET-MR system

Research output: Chapter in Book/Report/Conference proceedingConference paperpeer-review

Abstract

Respiratory motion remains a challenge for coronary MR angiography at 3T. Here we propose an inline 2D translational motion correction scheme using an image-based navigator. Low-resolution navigators are acquired at each heartbeat by spatially encoding the start-up echoes of an ECG-gated gradient echo sequence, allowing for 100% scan efficiency. Results from healthy volunteers show that motion correction improves visualization of the right and left anterior descending coronary arteries. The proposed scheme potentially allows for performing a comprehensive diagnosis of coronary artery disease by acquiring both diagnostic and motion information from MR, that can also be used to correct PET data.
Original languageEnglish
Title of host publicationProceedings of the 24th Annual Meeting of ISMRM, Singapore
PublisherISMRM
Pages2204
Publication statusPublished - 2016