TY - JOUR
T1 - A 0/1h-algorithm using cardiac myosin-binding protein C for early diagnosis of myocardial infarction
AU - APACE Investigators
AU - Kaier, Thomas E
AU - Twerenbold, Raphael
AU - Lopez-Ayala, Pedro
AU - Nestelberger, Thomas
AU - Boeddinghaus, Jasper
AU - Alaour, Bashir
AU - Huber, Iris-Martina
AU - Zhi, Yuan
AU - Koechlin, Luca
AU - Wussler, Desiree
AU - Wildi, Karin
AU - Shrestha, Samyut
AU - Strebel, Ivo
AU - Miro, Oscar
AU - Martín-Sánchez, Javier F
AU - Christ, Michael
AU - Kawecki, Damien
AU - Keller, Dagmar I
AU - Rubini Gimenez, Maria
AU - Marber, Michael
AU - Mueller, Christian
N1 - © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology.
PY - 2022/2/12
Y1 - 2022/2/12
N2 - AIMS : Cardiac myosin-binding protein C (cMyC) demonstrated high diagnostic accuracy for the early detection of non-ST-elevation myocardial infarction (NSTEMI). Its dynamic release kinetics may enable a 0/1h-decision algorithm that is even more effective than the ESC hs-cTnT/I 0/1 h rule-in/rule-out algorithm.METHODS AND RESULTS : In a prospective international diagnostic study enrolling patients presenting with suspected NSTEMI to the emergency department, cMyC was measured at presentation and after 1 h in a blinded fashion. Modelled on the ESC hs-cTnT/I 0/1h-algorithms, we derived a 0/1h-cMyC-algorithm. Final diagnosis of NSTEMI was centrally adjudicated according to the 4th Universal Definition of Myocardial Infarction. Among 1495 patients, the prevalence of NSTEMI was 17%. The optimal derived 0/1h-algorithm ruled-out NSTEMI with cMyC 0 h concentration below 10 ng/L (irrespective of chest pain onset) or 0 h cMyC concentrations below 18 ng/L and 0/1 h increase <4 ng/L. Rule-in occurred with 0 h cMyC concentrations of at least 140 ng/L or 0/1 h increase ≥15 ng/L. In the validation cohort (n = 663), the 0/1h-cMyC-algorithm classified 347 patients (52.3%) as 'rule-out', 122 (18.4%) as 'rule-in', and 194 (29.3%) as 'observe'. Negative predictive value for NSTEMI was 99.6% [95% confidence interval (CI) 98.9-100%]; positive predictive value 71.1% (95% CI 63.1-79%). Direct comparison with the ESC hs-cTnT/I 0/1h-algorithms demonstrated comparable safety and even higher triage efficacy using the 0h-sample alone (48.1% vs. 21.2% for ESC hs-cTnT-0/1 h and 29.9% for ESC hs-cTnI-0/1 h; P < 0.001).CONCLUSION : The cMyC 0/1h-algorithm provided excellent safety and identified a greater proportion of patients suitable for direct rule-out or rule-in based on a single measurement than the ESC 0/1h-algorithm using hs-cTnT/I.TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587.
AB - AIMS : Cardiac myosin-binding protein C (cMyC) demonstrated high diagnostic accuracy for the early detection of non-ST-elevation myocardial infarction (NSTEMI). Its dynamic release kinetics may enable a 0/1h-decision algorithm that is even more effective than the ESC hs-cTnT/I 0/1 h rule-in/rule-out algorithm.METHODS AND RESULTS : In a prospective international diagnostic study enrolling patients presenting with suspected NSTEMI to the emergency department, cMyC was measured at presentation and after 1 h in a blinded fashion. Modelled on the ESC hs-cTnT/I 0/1h-algorithms, we derived a 0/1h-cMyC-algorithm. Final diagnosis of NSTEMI was centrally adjudicated according to the 4th Universal Definition of Myocardial Infarction. Among 1495 patients, the prevalence of NSTEMI was 17%. The optimal derived 0/1h-algorithm ruled-out NSTEMI with cMyC 0 h concentration below 10 ng/L (irrespective of chest pain onset) or 0 h cMyC concentrations below 18 ng/L and 0/1 h increase <4 ng/L. Rule-in occurred with 0 h cMyC concentrations of at least 140 ng/L or 0/1 h increase ≥15 ng/L. In the validation cohort (n = 663), the 0/1h-cMyC-algorithm classified 347 patients (52.3%) as 'rule-out', 122 (18.4%) as 'rule-in', and 194 (29.3%) as 'observe'. Negative predictive value for NSTEMI was 99.6% [95% confidence interval (CI) 98.9-100%]; positive predictive value 71.1% (95% CI 63.1-79%). Direct comparison with the ESC hs-cTnT/I 0/1h-algorithms demonstrated comparable safety and even higher triage efficacy using the 0h-sample alone (48.1% vs. 21.2% for ESC hs-cTnT-0/1 h and 29.9% for ESC hs-cTnI-0/1 h; P < 0.001).CONCLUSION : The cMyC 0/1h-algorithm provided excellent safety and identified a greater proportion of patients suitable for direct rule-out or rule-in based on a single measurement than the ESC 0/1h-algorithm using hs-cTnT/I.TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587.
U2 - 10.1093/ehjacc/zuac007
DO - 10.1093/ehjacc/zuac007
M3 - Article
C2 - 35149868
SN - 2048-8726
JO - European heart journal. Acute cardiovascular care
JF - European heart journal. Acute cardiovascular care
ER -