A Technique for Measuring Anisotropy in Atrial Conduction to Estimate Conduction Velocity and Atrial Fibre Direction

Research output: Contribution to journalArticlepeer-review

45 Citations (Scopus)
118 Downloads (Pure)

Abstract

Cardiac conduction properties exhibit large variability, and affect patient-specific arrhythmia mechanisms. However, it is challenging to clinically measure conduction velocity (CV), anisotropy and fibre direction. Our aim is to develop a technique to estimate conduction anisotropy and fibre direction from clinically available electrical recordings. Methods: We developed and validated automated algorithms for estimating cardiac CV anisotropy, from any distribution of recording locations on the atrial surface. The first algorithm is for elliptical wavefront fitting to a single activation map (method 1), which works well close to the pacing location, but decreases in accuracy further from the pacing location (due to spatial heterogeneity in the conductivity and fibre fields). As such, we developed a second methodology for measuring local conduction anisotropy, using data from two or three activation maps (method 2: ellipse fitting to wavefront propagation velocity vectors from multiple activation maps). Results: Ellipse fitting to CV vectors from two activation maps (method 2) leads to an improved estimation of longitudinal and transverse CV compared to method 1, but fibre direction estimation is still relatively poor. Using three activation maps with method 2 provides accurate estimation, with approximately 70% of atrial fibres estimated within 20 degrees. We applied the technique to clinical activation maps to demonstrate the presence of heterogeneous conduction anisotropy, and then tested the effects of this conduction anisotropy on predicted arrhythmia dynamics using computational simulation. Conclusions: We have developed novel algorithms for calculating CV and measuring the direction dependency of atrial activation to estimate atrial fibre direction, without the need for specialised pacing protocols, using clinically available electrical recordings.
Original languageEnglish
Pages (from-to)278-290
JournalComputers in Biology and Medicine
Volume104
Early online date1 Nov 2018
DOIs
Publication statusPublished - Jan 2019

Keywords

  • Conduction Velocity
  • Anisotropy
  • Atrial Fibres
  • Atrial fibrillation
  • Fibrosis

Fingerprint

Dive into the research topics of 'A Technique for Measuring Anisotropy in Atrial Conduction to Estimate Conduction Velocity and Atrial Fibre Direction'. Together they form a unique fingerprint.

Cite this