Abstract
PURPOSE: To achieve 3D T2 w imaging of the prostate with 1-mm isotropic resolution in less than 3 min.
METHODS: We devised and implemented a 3D T2 -prepared multishot balanced steady state free precession (T2 prep-bSSFP) acquisition sequence with a variable density undersampled trajectory combined with a total variation regularized iterative SENSE (TV-SENSE) reconstruction. Prospectively undersampled images of the prostate (acceleration factor R = 3) were acquired in 11 healthy subjects in an institutional review board-approved study. Image quality metrics (subjective signal-to-noise ratio, contrast, sharpness, and overall prostate image quality) were evaluated by 2 radiologists. Scores of the proposed accelerated sequence were compared using the Wilcoxon signed-rank and Kruskal-Wallis non-parametric tests to prostate images acquired using a fully sampled 3D T2 prep-bSSFP acquisition, and with clinical standard 2D and 3D turbo spin echo (TSE) T2 w acquisitions. A P-value < 0.05 was considered significant.
RESULTS: The 3× accelerated 3D T2 prep-bSSFP images required a scan time (min:s) of 2:45, while the fully sampled 3D T2 prep-bSSFP and clinical standard 3D TSE images were acquired in 8:23 and 7:29, respectively. Image quality scores (contrast, sharpness, and overall prostate image quality) of the accelerated 3D T2 prep-bSSFP, fully sampled T2 prep-bSSFP, and clinical standard 3D TSE acquisitions along all 3 spatial dimensions were not significantly different (P > 0.05).
CONCLUSION: 3D T2 w images of the prostate with 1-mm isotropic resolution can be acquired in less than 3 min, with image quality that is comparable to a clinical standard 3D TSE sequence but only takes a third of the acquisition time.
Original language | English |
---|---|
Pages (from-to) | 721-731 |
Number of pages | 11 |
Journal | Magnetic Resonance in Medicine |
Volume | 82 |
Issue number | 2 |
Early online date | 21 Apr 2019 |
DOIs | |
Publication status | Published - Aug 2019 |
Keywords
- 3D prostate imaging
- T -weighted MRI
- TV-SENSE
- fast imaging
- isotropic resolution