Assessing long-term survival and hospitalization following transvenous lead extraction in patients with cardiac resynchronization therapy devices: A propensity score-matched analysis

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Longer-term outcomes of patients post transvenous lead extraction (TLE) are poorly understood in patients with cardiac resynchronization therapy (CRT) devices. A propensity score (PS)-matched analysis evaluating outcomes post TLE in CRT and non-CRT populations was performed. Data from consecutive patients undergoing TLE between 2000 and 2019 were prospectively collected. Patients surviving to discharge and reimplanted with the same device were included. The cohort was split depending on presence of CRT device. Associations with all-cause mortality and hospitalization were assessed by Kaplan-Meier estimates. An exploratory endpoint was evaluated whether early (7 days) reimplantation was associated with poorer outcomes. Of 1005 patients included, 285 (25%) had a CRT device. Median follow-up was 57.00 [27.00-93.00] months, age at explant was 67.7 ± 12.1 years, 83.3% were male, and 54.4% had an infective indication for TLE. PS was calculated using 43 baseline characteristics. After matching, 192 CRT patients were compared with 192 non-CRT patients. In the matched cohort, no significant difference with respect to mortality (hazard ratio [HR] = 1.01, 95% confidence interval [CI] [0.74-1.39], = .093) or hospitalization risk (HR = 1.2, 95% CI [0.87-1.66], = .265) was observed. In the matched CRT group, late reimplantation was associated with increased mortality (HR = 1.64, [1.04-2.57], = .032) and hospitalization risk (HR = 1.57, 95% CI [1.00-2.46], = .049]. Outcomes of CRT patients post TLE are similarly as poor as those of non-CRT patients in matched populations. Reimplantation within 7 days was associated with better outcomes in a CRT population but was not observed in a non-CRT population, suggesting prolonged periods without biventricular pacing should be avoided. [Abstract copyright: © 2021 Heart Rhythm Society. Published by Elsevier Inc.]
Original languageEnglish
Pages (from-to)597-606
JournalHeart Rhythm O2
Volume2
Issue number6Part A
DOIs
Publication statusE-pub ahead of print - 17 Dec 2021

Keywords

  • Mortality
  • Propensity score matching
  • Hospitalization
  • Transvenous lead extraction
  • CRT
  • Cardiac resynchronization therapy

Fingerprint

Dive into the research topics of 'Assessing long-term survival and hospitalization following transvenous lead extraction in patients with cardiac resynchronization therapy devices: A propensity score-matched analysis'. Together they form a unique fingerprint.

Cite this