Development of a Flow Phantom for Transcranial Doppler Ultrasound Quality Assurance

Fatmah Alablani, Justyna Janus, Edward Pallett, Toni M. Mullins, Alanoud Almudayni, Emma M.L. Chung*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Anecdotal evidence was recently brought to our attention suggesting a potential difference in velocity estimates between transcranial Doppler (TCD) systems when measuring high velocities (∼200 cm/s) close to the threshold for sickle cell disease stroke prevention. As we were unable to identify a suitable commercial TCD phantom, a middle cerebral artery (MCA) flow phantom was developed to evaluate velocity estimates from different devices under controlled conditions. Time-averaged velocity estimates were obtained using two TCD devices: a Spencer Technologies ST3 Doppler system (ST3 PMD150, Spencer Technologies, Seattle, WA, USA) and a DWL Dopplerbox (DWL Compumedics, SN-300947, Singen, Germany). These were compared with velocity estimates obtained using a Zonare duplex scanner (Zonare Medical Systems, Mountain View, CA, USA), with timed collection of fluid as the gold standard. Bland–Altman analysis was performed to compare measurements between devices. Our tests confirmed that velocities measured with the DWL TCD system were +4.1 cm/s (+3.7%; limits of agreement [LoA]: 2%, 5%; p = 0.03) higher than the Spencer system when measuring a velocity 110 cm/s and +12 cm/s higher (+5.7 %; LoA: 4.8%, 6.6%; p = 0.03) when measuring velocities of 210 cm/s, close to the diagnostic threshold for stroke intervention. We found our MCA phantom to be a valuable tool for systematically quantifying differences in TCD velocity estimates between devices, confirming that the DWL system gave consistently higher readings than the Spencer ST3 system. Differences become more pronounced at high velocities, which explains why they were not identified earlier. Our findings have clinical implications for centers using TCD to monitor patients with sickle cell disease, as extra care may be needed to adjust for bias between manufacturers when making treatment decisions about children with sickle cell with velocities close to the diagnostic threshold.

Original languageEnglish
Pages (from-to)2302-2309
Number of pages8
JournalUltrasound in Medicine and Biology
Volume48
Issue number11
DOIs
Publication statusPublished - Nov 2022

Keywords

  • Cerebral blood flow velocity
  • Flow phantom
  • Middle cerebral artery
  • Quality Assurance
  • Sickle cell anemia
  • Transcranial Doppler ultrasound

Fingerprint

Dive into the research topics of 'Development of a Flow Phantom for Transcranial Doppler Ultrasound Quality Assurance'. Together they form a unique fingerprint.

Cite this