Does closed-loop automated oxygen control reduce the duration of mechanical ventilation? A randomised controlled trial in ventilated preterm infants

Ourania Kaltsogianni, Theodore Dassios*, Anne Greenough

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)
58 Downloads (Pure)

Abstract

Background: Many preterm infants require supplemental oxygen in the newborn period but experience frequent fluctuations of their oxygen saturation levels. Intermittent episodes of hypoxia or hyperoxia increase the risk of complications. Compliance with achievement of oxygen saturation targets is variable, and the need for frequent adjustments of the inspired oxygen concentration increases workload. Closed-loop automated oxygen control systems (CLAC) improve achievement of oxygen saturation targets and reduce both episodes of hypoxia and hyperoxia and the number of manual adjustments. This study investigates whether CLAC compared with manual oxygen control reduces the duration of mechanical ventilation in preterm infants born at less than 31 weeks of gestation. Methods: This randomised controlled trial performed at a single tertiary neonatal unit is recruiting 70 infants born at less than 31 weeks of gestational age and within 48 h of initiation of mechanical ventilation. Infants are randomised to CLAC or manual oxygen control from recruitment until successful extubation. The primary outcome is the duration of mechanical ventilation, and secondary outcomes are the percentage of time spent within target oxygen saturation ranges, the time spent in hypoxia or hyperoxia, the number of manual adjustments required, the number of days on oxygen, the incidence of bronchopulmonary dysplasia and the length and cost of neonatal unit stay. The study is performed following informed parental consent and was approved by the Yorkshire and the Humber-Sheffield Research Ethics Committee (protocol version 1.1, 13 July 2021). Discussion: This trial will investigate the effect of CLAC on the duration of mechanical ventilation, which is an important clinical outcome as prolonged mechanical ventilation is associated with important adverse outcomes, such as bronchopulmonary dysplasia. Trial registration: ClinicalTrials.Gov NCT05030337. Registered on 17 August 2021.

Original languageEnglish
Article number276
JournalTrials
Volume23
Issue number1
DOIs
Publication statusPublished - 8 Apr 2022

Keywords

  • Closed loop automated oxygen control
  • Intermittent hypoxemia and hyperoxemia
  • Mechanical ventilation
  • Preterm infants

Fingerprint