Research output: Contribution to journal › Article › peer-review
Salvatore Sauro, Irina Makeeva, Vicente Faus-Matoses, Federico Foschi, Massimo Giovarruscio, Paula Maciel Pires, Maria Elisa Martins Moura, Aline Almeida Neves, Vicente Faus-Llácer
Original language | English |
---|---|
Article number | 722 |
Journal | Materials |
Volume | 12 |
Issue number | 5 |
Early online date | 1 Mar 2019 |
DOIs | |
Accepted/In press | 25 Feb 2019 |
E-pub ahead of print | 1 Mar 2019 |
Additional links |
Effects of Ions-Releasing_SAURO_Accepted25Feb2020_GOLD VoR
materials_12_00722_v2.pdf, 2.18 MB, application/pdf
Uploaded date:01 Jul 2020
Version:Final published version
Licence:CC BY
This study aimed at evaluating the microtensile bond strength (MTBS) and fractographic features of dentine-bonded specimens created using universal adhesives applied in etch-and-rinse (ER) or self-etching (SE) mode in combination with modern ion-releasing resin-modified glass-ionomer cement (RMGIC)-basedmaterials after load cycling and artificial saliva aging. Two universal adhesives (FTB: Futurabond M+, VOCO, Germany; SCU: Scotchbond Universal, 3M Oral Care, USA) were used. Composite build-ups were made with conventional nano-filled composite (AURA, SDI, Australia), conventional resin-modified glass ionomer cement (Ionolux VOCO, Germany), or a (RMGIC)-based composite (ACTIVA, Pulpdent, USA). The specimens were divided in three groups and immersed in deionized water for 24 h, load-cycled (350,000 cycles; 3 Hz; 70 N), or load-cycled and cut into matchsticks and finally immersed for 8 months in artificial saliva (AS). The specimens were cut into matchsticks and tested for microtensile bond strength. The results were analyzed statistically using three-way ANOVA and Fisher's LSD post hoc test (p < 0.05). Fractographic analysis was performed through stereomicroscope and FE-SEM. FTB showed no significant drop in bond strength after aging. Unlike the conventional composite, the two RMGIC-based materials caused no bond strength reduction in SCU after load-cycle aging and after prolonged aging (8 months). The SEM fractographic analysis showed severe degradation, especially with composite applied on dentine bonded with SCU in ER mode; such degradation was less evident with the two GIC-based materials. The dentine-bond longevity may be influenced by the composition rather than the mode of application (ER vs. SE) of the universal adhesives. Moreover, the choice of the restorative material may play an important role on the longevity of the finalrestoration. Indeed, bioactive GIC-based materials may contribute to maintain the bonding performance of simplified universal adhesives over time, especially when these bonding systems are applied in ER mode.
King's College London - Homepage
© 2020 King's College London | Strand | London WC2R 2LS | England | United Kingdom | Tel +44 (0)20 7836 5454