TY - JOUR
T1 - Experimental validation of estimated spatially variant radioisotope-specific point spread functions using published positron range simulations and fluorine-18 measurements
AU - Anton-Rodriguez, Jose M
AU - Krokos, Georgios
AU - Kotasidis, Fotis
AU - Asselin, Marie-Claude
AU - Morris, Olivia
AU - Julyan, Peter
AU - Archer, Anthony
AU - Matthews, Julian C
PY - 2018/12/7
Y1 - 2018/12/7
N2 - In this work we compare spatially variant radioisotope-specific point spread functions (PSFs) derived from published positron range data with measured data using a high resolution research tomograph (HRRT). Spatially variant PSFs were measured on a HRRT for fluorine-18, carbon-11 and gallium-68 using an array of printed point sources. For gallium-68, this required modification of the original design to handle its longer positron range. Using the fluorine-18 measurements and previously published data from Monte-Carlo simulations of positron range, estimated PSFs for carbon-11 and gallium-68 were calculated and compared with experimental data. A double 3D Gaussian function was fitted to the estimated and measured data and used to model the spatially varying PSFs over the scanner field of view (FOV). Differences between the measured and estimated PSFs were quantified using the full-width-at-half-maximum (FWHM) and full-width-at-tenth-maximum (FWTM) in the tangential, radial and axial directions. While estimated PSFs were generally in agreement with the measured PSFs over the entire FOV better agreement was observed (FWHM and FWTM differences of less than 10%) when using one of the two sets of positron range simulations, especially for gallium-68 and for the FWTM. Spatially variant radioisotope specific PSFs can be accurately estimated from fluorine-18 measurements and published positron range data. We have experimentally validated this approach for carbon-11 and gallium-68, and such an approach may be applicable to other radioisotopes such as oxygen-15 for which measurements are not practical.
AB - In this work we compare spatially variant radioisotope-specific point spread functions (PSFs) derived from published positron range data with measured data using a high resolution research tomograph (HRRT). Spatially variant PSFs were measured on a HRRT for fluorine-18, carbon-11 and gallium-68 using an array of printed point sources. For gallium-68, this required modification of the original design to handle its longer positron range. Using the fluorine-18 measurements and previously published data from Monte-Carlo simulations of positron range, estimated PSFs for carbon-11 and gallium-68 were calculated and compared with experimental data. A double 3D Gaussian function was fitted to the estimated and measured data and used to model the spatially varying PSFs over the scanner field of view (FOV). Differences between the measured and estimated PSFs were quantified using the full-width-at-half-maximum (FWHM) and full-width-at-tenth-maximum (FWTM) in the tangential, radial and axial directions. While estimated PSFs were generally in agreement with the measured PSFs over the entire FOV better agreement was observed (FWHM and FWTM differences of less than 10%) when using one of the two sets of positron range simulations, especially for gallium-68 and for the FWTM. Spatially variant radioisotope specific PSFs can be accurately estimated from fluorine-18 measurements and published positron range data. We have experimentally validated this approach for carbon-11 and gallium-68, and such an approach may be applicable to other radioisotopes such as oxygen-15 for which measurements are not practical.
KW - Carbon Radioisotopes/analysis
KW - Computer Simulation
KW - Electrons
KW - Fluorine Radioisotopes/analysis
KW - Gallium Radioisotopes/analysis
KW - Humans
KW - Image Processing, Computer-Assisted/methods
KW - Monte Carlo Method
KW - Oxygen Radioisotopes/analysis
KW - Phantoms, Imaging
KW - Positron-Emission Tomography/methods
U2 - 10.1088/1361-6560/aaecb6
DO - 10.1088/1361-6560/aaecb6
M3 - Article
C2 - 30524089
SN - 0031-9155
VL - 63
SP - 24NT01
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
IS - 24
ER -