High-frame-rate tri-plane echocardiography with spiral arrays: From simulation to real-time implementation

Alessandro Ramalli*, Sevan Harput, Stephanie Bezy, Enrico Boni, Robert J. Eckersley, Piero Tortoli, Jan D'Hooge

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

27 Citations (Scopus)

Abstract

Major cardiovascular diseases (CVDs) are associated with (regional) dysfunction of the left ventricle. Despite the 3-D nature of the heart and its dynamics, the assessment of myocardial function is still largely based on 2-D ultrasound imaging, thereby making diagnosis heavily susceptible to the operator's expertise. Unfortunately, to date, 3-D echocardiography cannot provide adequate spatiotemporal resolution in real-time. Hence, tri-plane imaging has been introduced as a compromise between 2-D and true volumetric ultrasound imaging. However, tri-plane imaging typically requires high-end ultrasound systems equipped with fully populated matrix array probes embedded with expensive and little flexible electronics for two-stage beamforming. This article presents an advanced ultrasound system for real-time, high frame rate (HFR), and tri-plane echocardiography based on low element count sparse arrays, i.e., the so-called spiral arrays. The system was simulated, experimentally validated, and implemented for real-time operation on the ULA-OP 256 system. Five different array configurations were tested together with four different scan sequences, including multi-line and planar diverging wave transmission. In particular, the former can be exploited to achieve, in tri-plane imaging, the same temporal resolution currently used in clinical 2-D echocardiography, at the expenses of contrast (-3.5 dB) and signal-to-noise ratio (SNR) (-8.7 dB). On the other hand, the transmission of planar diverging waves boosts the frame rate up to 250 Hz, but further compromises contrast (-10.5 dB), SNR (-9.7 dB), and lateral resolution (+46%). In conclusion, despite an unavoidable loss in image quality and sensitivity due to the limited number of elements, HFR tri-plane imaging with spiral arrays is shown to be feasible in real-time and may enable real-time functional analysis of all left ventricular segments of the heart.

Original languageEnglish
Article number8832242
Pages (from-to)57-69
Number of pages13
JournalIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Volume67
Issue number1
DOIs
Publication statusPublished - 1 Jan 2020

Keywords

  • 3-D imaging
  • cardiac imaging
  • diverging waves
  • high-frame-rate (HFR) imaging
  • multiline transmission (MLT)
  • real-time
  • sparse arrays
  • spiral arrays
  • tri-plane echocardiography

Fingerprint

Dive into the research topics of 'High-frame-rate tri-plane echocardiography with spiral arrays: From simulation to real-time implementation'. Together they form a unique fingerprint.

Cite this