T1 - Joint system relaxometry (JSR) and Crámer-Rao lower bound optimization of sequence parameters
T2 - A framework for enhanced precision of DESPOT T1 and T2 estimation
AU - Teixeira, Rui Pedro A G
AU - Malik, Shaihan J.
AU - Hajnal, Joseph V.
N1 - © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
PY - 2017/3/16
Y1 - 2017/3/16
N2 - Purpose: This study aims to increase the precision of single-compartment DESPOT relaxometry by two means: (i) a joint system relaxometry (JSR) approach that estimates parameters in a single step using all available data; and (ii) optimizing acquisition parameters by deploying a robust design tool based on the Crámer-Rao lower bound (CRLB). Methods: Following the development of the analysis and design capabilities, phantom and four in vivo subject experiments were performed to compare directly the precision achieved with DESPOT and JSR estimation using published protocols and protocols designed using a proposed CRLB framework. Results: Experimental data demonstrate JSR's ability to decrease relaxometry estimation variance. Phantom results show 72 to 77% improvement using the same data as conventional DESPOT. This is further improved to 81 to 87% using optimal parameters. Both experiments show systematic bias depending on the acquisition parameters used, which are shown to be highly reproducible and to vary with different magnetization transfer conditions. Conclusions: Compared with DESPOT, JSR produces reproducible relaxation maps with improved precision. Further improvement was achieved using CRLB as a protocol design tool. With this combined approach, it is possible to achieve submillimeter maps of ρ,T1,T2, and B0 in an 11-min examination, making the approach appealing for potential clinical use.
AB - Purpose: This study aims to increase the precision of single-compartment DESPOT relaxometry by two means: (i) a joint system relaxometry (JSR) approach that estimates parameters in a single step using all available data; and (ii) optimizing acquisition parameters by deploying a robust design tool based on the Crámer-Rao lower bound (CRLB). Methods: Following the development of the analysis and design capabilities, phantom and four in vivo subject experiments were performed to compare directly the precision achieved with DESPOT and JSR estimation using published protocols and protocols designed using a proposed CRLB framework. Results: Experimental data demonstrate JSR's ability to decrease relaxometry estimation variance. Phantom results show 72 to 77% improvement using the same data as conventional DESPOT. This is further improved to 81 to 87% using optimal parameters. Both experiments show systematic bias depending on the acquisition parameters used, which are shown to be highly reproducible and to vary with different magnetization transfer conditions. Conclusions: Compared with DESPOT, JSR produces reproducible relaxation maps with improved precision. Further improvement was achieved using CRLB as a protocol design tool. With this combined approach, it is possible to achieve submillimeter maps of ρ,T1,T2, and B0 in an 11-min examination, making the approach appealing for potential clinical use.
KW - CRLB
KW - DESPOT
KW - Relaxometry
UR - http://www.scopus.com/inward/record.url?scp=85016598161&partnerID=8YFLogxK
U2 - 10.1002/mrm.26670
DO - 10.1002/mrm.26670
M3 - Article
C2 - 28303617
SN - 1522-2594
JO - Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine
JF - Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine
ER -