TY - JOUR
T1 - Model-based Vasculature Extraction from Optical Fluorescence Cryomicrotome Images
AU - Goyal, Ayush
AU - Lee, Jack
AU - Lamata de la Orden, Pablo
AU - van den Wijngaard, J.
AU - van Horssen, P.
AU - Spaan, J.
AU - Siebes, M.
AU - Grau, V.
AU - Smith, Nicolas
PY - 2012/11/15
Y1 - 2012/11/15
N2 - The aim of this study was to develop a novel method to reconstruct three-dimensional coronary vasculature from cryomicrotome images, comprised of two distinct sets of data fluorescent microsphere beads and coronary vasculature. Fluorescent beads and cast injected into the vasculature were separately imaged with different filter settings to obtain the microsphere and vascular data, respectively. To extract the vascular anatomy, light scattering in the tissue was modelled using a point spread function (PSF). The PSF was parametrized by optical tissue excitation and emission attenuation coefficients, which were estimated by fitting simulated images of microspheres convolved with the PSF model to the experimental microsphere images. These parameters were then applied within a new model-based method for vessel radius estimation. Current state-of-the-art radii estimation methods and the proposed model-based method were applied on vessel phantoms. In this validation study, the Full-Width Half Maximum method of radii estimation, when performed on the raw data without correcting for the optical blurring, resulted in 42.9% error on average for the 170ìm vessel. In comparison, the model-based method resulted in 0.6% error on average for the same phantom. Whole-organ porcine coronary vasculature was automatically reconstructed with the new model-based vascular extraction method.
AB - The aim of this study was to develop a novel method to reconstruct three-dimensional coronary vasculature from cryomicrotome images, comprised of two distinct sets of data fluorescent microsphere beads and coronary vasculature. Fluorescent beads and cast injected into the vasculature were separately imaged with different filter settings to obtain the microsphere and vascular data, respectively. To extract the vascular anatomy, light scattering in the tissue was modelled using a point spread function (PSF). The PSF was parametrized by optical tissue excitation and emission attenuation coefficients, which were estimated by fitting simulated images of microspheres convolved with the PSF model to the experimental microsphere images. These parameters were then applied within a new model-based method for vessel radius estimation. Current state-of-the-art radii estimation methods and the proposed model-based method were applied on vessel phantoms. In this validation study, the Full-Width Half Maximum method of radii estimation, when performed on the raw data without correcting for the optical blurring, resulted in 42.9% error on average for the 170ìm vessel. In comparison, the model-based method resulted in 0.6% error on average for the same phantom. Whole-organ porcine coronary vasculature was automatically reconstructed with the new model-based vascular extraction method.
KW - cryomicrotome imaging
KW - three-dimensional automatic reconstruction
KW - whole-organ coronary vasculature
KW - vascular extraction
U2 - 10.1109/TMI.2012.2227275
DO - 10.1109/TMI.2012.2227275
M3 - Article
SN - 0278-0062
JO - Ieee Transactions on Medical Imaging
JF - Ieee Transactions on Medical Imaging
IS - 99
ER -