TY - JOUR
T1 - Spatially-Compact MR-Guided Kernel EM for PET Image Reconstruction
AU - Bland, James
AU - Belzunce, Martin A.
AU - Ellis, Sam
AU - McGinnity, Colm Joseph
AU - Hammers, Alexander
AU - Reader, Andrew Jonathan
PY - 2018/6/6
Y1 - 2018/6/6
N2 - Positron emission tomography (PET) is a highly sensitive functional and molecular imaging modality which can measure picomolar concentrations of an injected radionuclide. However, the physical sensitivity of PET is limited, and reducing the injected dose leads to low count data and noisy reconstructed images. A highly effective way of reducing noise is to reparameterise the reconstruction in terms of MR-derived spatial basis functions. Spatial basis functions derived using the kernel method have demonstrated excellent noise reduction properties and maintain shared PET-MR detailed structures. However, as previously shown in the literature, the MR-guided kernel method may lead to excessive smoothing of structures that are only present in the PET data. This work makes two main contributions in order to address this problem: first, we exploit the potential of the MR-guided kernel method to form more spatially-compact basis functions which are able to preserve PET-unique structures, and secondly, we consider reconstruction at the native MR resolution. The former contribution notably improves the recovery of structures which are unique to the PET data. These adaptations of the kernel method were compared to the conventional implementation of the MR-guided kernel method and also to MLEM, in terms of ability to recover PET unique structures for both simulated and real data. The spatially-compact kernel method showed clear visual and quantitative improvements in the reconstruction of the PET unique structures, relative to the conventional kernel method for all sizes of PET unique structures investigated, whilst maintaining to a large extent the impressive noise mitigating and detail preserving properties of the conventional MR-guided kernel method. We therefore conclude that a spatially-compact parameterisation of the MR-guided kernel method, should be the preferred implementation strategy in order to obviate unnecessary losses in PET-unique details.
AB - Positron emission tomography (PET) is a highly sensitive functional and molecular imaging modality which can measure picomolar concentrations of an injected radionuclide. However, the physical sensitivity of PET is limited, and reducing the injected dose leads to low count data and noisy reconstructed images. A highly effective way of reducing noise is to reparameterise the reconstruction in terms of MR-derived spatial basis functions. Spatial basis functions derived using the kernel method have demonstrated excellent noise reduction properties and maintain shared PET-MR detailed structures. However, as previously shown in the literature, the MR-guided kernel method may lead to excessive smoothing of structures that are only present in the PET data. This work makes two main contributions in order to address this problem: first, we exploit the potential of the MR-guided kernel method to form more spatially-compact basis functions which are able to preserve PET-unique structures, and secondly, we consider reconstruction at the native MR resolution. The former contribution notably improves the recovery of structures which are unique to the PET data. These adaptations of the kernel method were compared to the conventional implementation of the MR-guided kernel method and also to MLEM, in terms of ability to recover PET unique structures for both simulated and real data. The spatially-compact kernel method showed clear visual and quantitative improvements in the reconstruction of the PET unique structures, relative to the conventional kernel method for all sizes of PET unique structures investigated, whilst maintaining to a large extent the impressive noise mitigating and detail preserving properties of the conventional MR-guided kernel method. We therefore conclude that a spatially-compact parameterisation of the MR-guided kernel method, should be the preferred implementation strategy in order to obviate unnecessary losses in PET-unique details.
KW - PET-MR
KW - Image reconstruction
U2 - 10.1109/TRPMS.2018.2844559
DO - 10.1109/TRPMS.2018.2844559
M3 - Article
SN - 2469-7303
JO - Transactions on Radiation and Plasma Medical Sciences
JF - Transactions on Radiation and Plasma Medical Sciences
ER -