The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: A cross-over study

Henry Chubb*, Rashed Karim, Sébastien Roujol, Marta Nuñez-Garcia, Steven E. Williams, John Whitaker, James Harrison, Constantine Butakoff, Oscar Camara, Amedeo Chiribiri, Tobias Schaeffter, Matthew Wright, Mark O'Neill, Reza Razavi

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

52 Citations (Scopus)
259 Downloads (Pure)

Abstract

Background: Cardiovascular magnetic resonance (CMR) imaging has been used to visualise post-ablation atrial scar (PAAS), generally employing a three-dimensional (3D) late gadolinium enhancement (LGE) technique. However the reproducibility of PAAS imaging has not been determined. This cross-over study is the first to investigate the reproducibility of the technique, crucial for both future research design and clinical implementation. Methods: Forty subjects undergoing first time ablation for atrial fibrillation (AF) had detailed CMR assessment of PAAS. Following baseline pre-ablation scan, two scans (separated by 48 h) were performed at three months post-ablation. Each scan session included 3D LGE acquisition at 10, 20 and 30 min post administration of gadolinium-based contrast agent (GBCA). Subjects were allocated at second scan post-ablation to identical imaging parameters ('Repro', n = 10), 3 T scanner ('3 T', n = 10), half-slice thickness ('Half-slice', n = 10) or half GBCA dose ('Half-gad', n = 10). PAAS was compared to baseline scar and then reproducibility was assessed for two measures of thresholded scar (% left atrial (LA) occupied by PAAS (%LA PAAS) and Pulmonary Vein Encirclement (PVE)), and then four measures of non-thresholded scar (point-by-point assessment of PAAS, four normalisation methods). Thresholded measures of PAAS were evaluated against procedural outcome (AF recurrence). Results: A total of 271 3D acquisitions (out of maximum 280, 96.7%) were acquired. At 20 and 30 min, inter-scan reproducibility was good to excellent (coefficient of variation at 20 min and 30 min: %LA PAAS 0.41 and 0.20; PVE 0.13 and 0.04 respectively for 'Repro' group). Changes in imaging parameters, especially reduced GBCA dose, reduced inter-scan reproducibility, but for most measures remained good to excellent (ICC for %LA PAAS 0.454-0.825, PVE 0.618-0.809 at 30 min). For non-thresholded scar, highest reproducibility was observed using blood pool z-score normalisation technique: inter-scan ICC 0.759 (absolute agreement, 'Repro' group). There was no significant relationship between indices of PAAS and AF recurrence. Conclusion: PAAS imaging is a reproducible finding. Imaging should be performed at least 20 min post-GBCA injection, and a blood pool z-score should be considered for normalisation of signal intensities. The clinical implications of these findings remain to be established in the absence of a simple correlation with arrhythmia outcome. Trial registration: United Kingdom National Research Ethics Service 08/H0802/68 - 30th September 2008.

Original languageEnglish
Article number21
JournalJournal of Cardiovascular Magnetic Resonance
Volume20
Issue number1
Early online date19 Mar 2018
DOIs
Publication statusE-pub ahead of print - 19 Mar 2018

Keywords

  • Atrial fibrillation
  • Atrium
  • Cardiac magnetic resonance imaging
  • Catheter ablation
  • Late gadolinium enhancement
  • Optimization